SCSI External Centronics 50 (Differential) Zurück


50 PIN CENTRONICS Buchse 50 PIN CENTRONICS Stift
50 PIN CENTRONICS Buchse
am controller & devices
50 PIN CENTRONICS Stift
am Kabel
Pin Name Bschreibung
1 GND Ground
2 +DB0 +Data Bus 0
3 +DB1 +Data Bus 1
4 +DB2 +Data Bus 2
5 +DB3 +Data Bus 3
6 +DB4 +Data Bus 4
7 +DB5 +Data Bus 5
8 +DB6 +Data Bus 6
9 +DB7 +Data Bus 7
10 +DBP +Data Bus Parity (odd Parity)
11 DIFFSENS ???
12 res Reserved
13 TERMPWR Termination Power
14 res Reserved
15 +ATN +Attention
16 GND Ground
17 +BSY +Bus is busy
18 +ACK +Acknowledge
19 +RST +Reset
20 +MSG +Message
21 +SEL +Select
22 +C/D +Control or Data
23 +REQ +Request
24 +I/O +In/Out
25 GND Ground
26 GND Ground
27 -DB0 -Data Bus 0
28 -DB1 -Data Bus 1
29 -DB2 -Data Bus 2
30 -DB3 -Data Bus 3
31 -DB4 -Data Bus 4
32 -DB5 -Data Bus 5
33 -DB6 -Data Bus 6
34 -DB7 -Data Bus Parity7
35 -DBP -Data Bus Parity (odd Parity)
36 GND Ground
37 res Reserved
38 TERMPWR Termination Power
39 res Reserved
40 -ATN -Attention
41 GND Ground
42 -BSY -Bus is busy
43 -ACK -Acknowledge
44 -RST -Reset
45 -MSG -Message
46 -SEL -Select
47 -C/D -Control or Data
48 -REQ -Request
49 -I/O -In/Out
50 GND Ground
Zurück